Hamer Fires 5 Series: Basset 5 / 5 Tall - Catalog - Page 5
COMMISSIONING AND WARRANTY CHECKLIST
Technical info
Nominal Heat Output
Ef昀椀ciency
Weight
Recommended Fuels
DEFRA
Flue Outlet Size (Top
or Rear Option)
Rear Flue Adaptor
Flue/Chimney Size
Flue/Chimney
minimum height**
Flue Draught
Ventilation
Hearth size (heat
shield must not to be
removed)
Appliance distance to
combustibles (heat
shield must not to be
removed, Twin Wall
Flue)
Appliance distance to
non combustibles
Parts Disassembly
Air Control Settings
Lighting Method
Wood
Solid fuel
Wood
Solid Fuel
Basset 5
Basset 5 Tall
Wood
kW
kW
%
%
Kg
Kg
4.9
4.6
81.9
77.6
130
135
This appliance requires a suitable adapter to 昀椀t to a 昀氀ue to a minimum dimension of
mm
125
It is recommended to install a sweep access point on the pipe connected to the adaptor.
Without 昀氀ue liner Round (Diameter)
mm
125
Seasoned Wood (less than 20% moisture content)
Briquette
smokeless fuel suitable for closed appliances (Mineral FuelSolid Fuel
Phuracite-Maxibrite-Taybrite-Home昀椀re Ovals)
The Basset 5 & Basset 5 tall comes factory 昀椀tted with a DEFRA secondary air stop which is 昀椀xed
and cannot be removed or adjusted.
Without 昀氀ue liner system (Square)
mm
135
With Liner of Factory made system (diameter) installed in accordance with
mm
125
manufacturers instructions
All products **must be 4.5m from the stove top to the top of the 昀氀ue, with no
horizontal sections and a maximum of 4 bends. Bends must have angles of less than Meter 4.5
45 degrees or less from the vertical.
Min
12
Pa
Max
25
Test point location on the top of the stove. Lift the stove lid up to expose draught test point. This
test point can be removed to perform the draught test.
See page 23
Additional
Ventilation
Traditionally Built Homes. Where leakage is greater than 5m3/
hour/m2. Ventilation required = 550mm2 per kW output over
5kW
Modern Construction Homes. Where leakage is less than 5m3/
hour/m2. Ventilation required = 550mm2 per kW
Minimum - Hearth thickness Superimposed
Minimum - In front of the stove
Minimum - Both sides of the stove
Minimum - Square free standing super imposed hearth both directions
Side Wall level with the front of the stove
Rear Wall
Projected side wall 100mm in front of stove
Corner Stove
Soft Furnishings in front of the appliance
Side Wall
Rear Wall - measured from the lid of the stove not heat shield
Corner Stove
mm2
cm2
in2
mm2
N/A
N/A
N/A
2750
cm2 27.5
0
in2
4.3
mm
12
mm
350
mm
150
mm
850
mm
290
mm
250
mm
290
mm
200
Meter
1
mm
100
mm
60
mm
50
See Page 26 - 30
See page 48 - 49
Top Down Method See Page 51
5