Hamer Fires 5 Series: Basset 5 / 5 Tall - Catalog - Page 31
INSTALLATION
Flue Outlet Con昀椀guration
The 昀氀ue collar and blanking plate positions can be adjusted based on the installation requirements. Each
part features a ceramic gasket to ensure a proper seal.
Top Outlet Con昀椀guration
Position the 昀氀ue collar over the top outlet. Install the M6 昀氀anged bolts through the keyhole slots in the
collar. Align the ceramic gasket between the 昀氀ue collar and the appliance. Twist the collar slightly to lock
it into position. Fully tighten the bolts to secure the 昀氀ue collar in place.
Rear Outlet Con昀椀guration
Remove the heat shield followed by the blanking plate from the rear outlet of the appliance. Bolt the
blanking plate inside the appliance to block the top 昀氀ue exit.
31