Hamer Fires 5 Series: Basset 5 / 5 Tall - Catalog - Page 18
STOVE DISTANCES
Stove Distances to Combustibles and Non-Combustibles
Combustible material should not be located where the heat dissipating through the walls of 昀椀replaces or
昀氀ues could ignite it. Therefore when installing the stove in the presence of combustible materials due
account must be taken of the guidance on the separation of combustible material given in Building
Regulations Approved Document J. The heat shield must not be removed
B
D
A
D
C
Vertical Rear Flue Adaptor can not be installed in this setting
DISTANCE TO COMBUSTIBLE MATERIALS TWIN WALL FLUE
Side Wall level with the front of the stove
A
290mm
Rear Wall
B
250mm
Projected side wall 100mm in front of stove
C
290mm
Corner Stove
D
200mm
B
C
A
C
Vertical Rear Flue Adaptor can be installed in this setting
DISTANCE TO NON-COMBUSTIBLE MATERIALS
Side Wall
A
100mm
Rear Wall
measured from the lid of the stove not heat shield
B
60mm
Corner Stove
C
50mm
18
SISB5 - REV1.7 / Issue Date 09-04-2025