HEARTHS
Hearth Requirements
A hearth is made up of 2 layers: a constructional hearth base concrete layer and a superimposed hearth
top decorative layer.
The heat shield reduced the under stove temperature to well below 100°C. If the heat shield is 昀椀tted as
standard the stove can be installed upon a 12mm non-combustible hearth, and there is no requirement
for a full constructional hearth.
If the heat shield is removed then a full construction hearth will be required in accordance to building
regulations.
B
B
A
B
B
Hearth Sizes
C
A
C
16
SISB5 - REV1.7 / Issue Date 09-04-2025
Hearth
thickness
Superimposed 12mm
(minimum)
In front of the
stove
350mm Minimum
A
Both sides of
the stove
150mm Minimum
B
Free standing
super imposed
hearth
850mm x 850mm Minimum
C